Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    In: Artificial Organs, Wiley, Vol. 42, No. 2 ( 2018-02), p. 155-165
    Kurzfassung: As it is common for patients treated with extracorporeal life support (ECLS) to subsequently require continuous renal replacement therapy (CRRT), and neonatal patients encounter limitations due to lack of access points, inclusion of CRRT in the ECLS circuit could provide advanced treatment for this population. The objective of this study was to evaluate an alternative neonatal ECLS circuit containing either a Maquet RotaFlow centrifugal pump or Maquet HL20 roller pump with one of seven configurations of CRRT using the Prismaflex 2000 System. All ECLS circuit setups included a Quadrox‐iD Pediatric diffusion membrane oxygenator, a Better Bladder, an 8‐Fr arterial cannula, a 10‐Fr venous cannula, and 6 feet of ¼‐inch diameter arterial and venous tubing. The circuit was primed with lactated Ringer's solution and packed human red blood cells resulting in a total priming volume of 700 mL for both the circuit and the 3‐kg pseudopatient. Hemodynamic data were recorded for ECLS flow rates of 200, 400, and 600 mL/min and a CRRT flow rate of 50 mL/min. When a centrifugal pump is used, the hemodynamic performance of any combined ECLS and CRRT circuit was not significantly different than that of the circuit without CRRT, thus any configuration could potentially be used. However, introduction of CRRT to a circuit containing a roller pump does affect performance properties for some CRRT positions. The circuits with CRRT positions B and G demonstrated decreased total hemodynamic energy (THE) levels at the post‐arterial cannula site, while positions D and E demonstrated increased post‐arterial cannula THE levels compared to the circuit without CRRT. CRRT positions A, C, and F did not have significant changes with respect to pre‐arterial cannula flow and THE levels, compared to the circuit without CRRT. Considering hemodynamic performance, for neonatal combined extracorporeal membrane oxygenation (ECMO) and CRRT circuits with both blood pumps, we recommend the use of CRRT position A due to its hemodynamic similarities to the ECMO circuit without CRRT.
    Materialart: Online-Ressource
    ISSN: 0160-564X , 1525-1594
    URL: Issue
    Sprache: Englisch
    Verlag: Wiley
    Publikationsdatum: 2018
    ZDB Id: 2003825-2
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz