    In: Journal of Cardiovascular Electrophysiology, Wiley, Vol. 29, No. 11 ( 2018-11), p. 1563-1569
    Abstract: Pulmonary delivery of flecainide results in the rapid conversion of atrial fibrillation (AF) to normal sinus rhythm in large‐animal models and is safe and well‐tolerated by normal human volunteers. Objective We investigated the effects of pulmonary delivery of flecainide on atrial and ventricular depolarization and repolarization duration. Methods Intratracheal instillation (1.5 mg/kg, rapid push) of flecainide or sterile water (placebo) was performed in 12 closed‐chest, anesthetized Yorkshire pigs with a catheter positioned at the bifurcation of the main bronchi. High‐resolution electrograms obtained from catheters fluoroscopically positioned in the right atrium and left ventricle circumvented measurement errors due to the fusion of P and T waves in surface leads when rapid heart rates shortened the TP interval. Pacing was achieved using electrical stimuli delivered via right atrial catheter electrodes. Results During sinus rhythm (98 ± 4.7 beats/min), intratracheal flecainide caused comparable ( P  = 0.56) increases in atrial depolarization (P a ) duration by 22% (39.8 ± 3.2 to 48.7 ± 3.3  milliseconds) and left ventricular (LV) QRS complex duration by 20% (47.9 ± 1.6 to 57.3 ± 1.8  milliseconds) at peak effect at 2 minutes post‐dosing. During right atrial pacing at 180 beats/min, P a duration increased by 55% (37.0 ± 2.0 to 57.2 ± 1.6  milliseconds; P   〈  0.0001). The atrial response was greater ( p  = 0.001) than the 30% increase in LV QRS complex duration (46.6 ± 1.7 to 60.6 ± 2.5  milliseconds; P  = 0.005). P a duration and QRS complex duration were unchanged by placebo independent of pacing ( P  ≥ 0.4 for both). Atrial repolarization duration (PT a ; P  = 0.46) and QT c interval ( P  = 0.49) remained unchanged. Conclusion Intratracheal flecainide exerts a rate‐dependent, predominant effect on atrial compared with ventricular depolarization duration. Pulmonary delivery of flecainide could facilitate AF conversion to sinus rhythm with reduced ventricular proarrhythmia risk.
    Type of Medium: Online Resource
    ISSN: 1045-3873 , 1540-8167
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2018
    detail.hit.zdb_id: 2037519-0
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages