Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Online-Ressource
    Online-Ressource
    American Society for Microbiology ; 2011
    In:  Journal of Clinical Microbiology Vol. 49, No. 3 ( 2011-03), p. 1025-1029
    In: Journal of Clinical Microbiology, American Society for Microbiology, Vol. 49, No. 3 ( 2011-03), p. 1025-1029
    Kurzfassung: The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated the detection of bacteria and leukocytes by a new urine analyzer, the UF-1000i, to identify negative urine samples that can be excluded from urine culture. In total, 1,577 urine samples were analyzed and compared to urine culture. Urine culture showed growth of ≥10 3 CFU/ml in 939 samples (60%). Receiver operating characteristics (ROC) curves and ROC decision plots were been prepared at three different gold standard definitions of a negative urine culture: no growth, growth of bacteria at 〈 10 4 CFU/ml, and growth of bacteria at 〈 10 5 CFU/ml. Also, the reduction in urine cultures and the percentage of false negatives were calculated. At the most stringent gold standard definition of no growth, a chosen sensitivity of 95% resulted in a cutoff value of 26 bacteria/μl, a specificity of 43% and a reduction in urine cultures of only 20%, of which 14% were false negatives. However, at a gold standard definition of 〈 10 5 CFU/ml and a sensitivity of 95%, the UF-1000i cutoff value was 230 bacteria/μl, the specificity was 80%, and the reduction in urine cultures was 52%, of which 0.3% were false negatives. The applicability of the UF-1000i to screen for negative urine samples strongly depends on population characteristics and the definition of a negative urine culture. In our setting, however, the low workload savings and the high percentage of false-negative results do not warrant the UF-1000i to be used as a screening analyzer.
    Materialart: Online-Ressource
    ISSN: 0095-1137 , 1098-660X
    RVK:
    Sprache: Englisch
    Verlag: American Society for Microbiology
    Publikationsdatum: 2011
    ZDB Id: 1498353-9
    SSG: 12
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz