In:
Journal of Clinical Microbiology, American Society for Microbiology, Vol. 52, No. 12 ( 2014-12), p. 4347-4349
Abstract:
We report here false-positive urinary Legionella pneumophila serogroup 1 and Streptococcus pneumoniae antigen test results due to rabbit antilymphocyte serum treatment and provide a simple and fast solution to rule them out by heating urine.
Type of Medium:
Online Resource
ISSN:
0095-1137
,
1098-660X
DOI:
10.1128/JCM.01916-14
Language:
English
Publisher:
American Society for Microbiology
Publication Date:
2014
detail.hit.zdb_id:
1498353-9
SSG:
12