In:
Respiration, S. Karger AG, Vol. 102, No. 3 ( 2023), p. 220-226
Abstract:
〈 b 〉 〈 i 〉 Background: 〈 /i 〉 〈 /b 〉 Endoscopic techniques, including endobronchial ultrasound (EBUS) and endoscopic ultrasound (EUS), are used as the initial approach for the diagnosis and staging of lung cancer and the diagnosis of thoracic and abdominal lesions. Historically, the transvascular approach has been avoided because of concerns about bleeding. 〈 b 〉 〈 i 〉 Objectives: 〈 /i 〉 〈 /b 〉 This article is a systematic review of studies evaluating the feasibility and safety of transvascular needle aspiration (TVNA) under the guidance of EBUS or EUS in the diagnosis of thoracic and abdominal lesions. 〈 b 〉 〈 i 〉 Methods: 〈 /i 〉 〈 /b 〉 We performed a systematic search of the MEDLINE, Embase, and Cochrane databases to identify studies evaluating the application of EBUS/EUS-guided TVNA (EBUS/EUS-TVNA) for lesions located at the contralateral side of the vessel for which the transvascular approach was the best puncture path. We performed a meta-analysis of diagnostic yield estimations. We also reviewed the complications related to the procedure. 〈 b 〉 〈 i 〉 Results: 〈 /i 〉 〈 /b 〉 Eleven observational studies were included in the final analysis. Meta-analysis yielded a pooled overall diagnostic yield of 82.10% (95% confidence interval, 0.74–0.89) for TVNA, with an 〈 i 〉 I 〈 /i 〉 〈 sup 〉 2 〈 /sup 〉 value of 52%. No publication bias was detected by Egger’s test ( 〈 i 〉 p 〈 /i 〉 = 0.8528). The overall complications included minor bleeding, minor hematoma, pseudoaneurysm of the aorta, hemoptysis, acute hypoxic respiratory failure, and moderate bleeding. The major complication rate was 2.71%. 〈 b 〉 〈 i 〉 Conclusions: 〈 /i 〉 〈 /b 〉 EBUS/EUS-TVNA is feasible and probably safe when performed by experienced endoscopists in carefully selected patients. In view of the potential risks associated with the transvascular approach, especially the development of hematoma and pseudoaneurysm, the fanning technique was avoided, and the area of aspiration should be assessed by EUS for 3 min after each aspiration. Most importantly, EBUS/EUS-TVNA should only be performed if the results will impact the clinical management.
Type of Medium:
Online Resource
ISSN:
0025-7931
,
1423-0356
Language:
English
Publisher:
S. Karger AG
Publication Date:
2023
detail.hit.zdb_id:
1464419-8