Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Journal of the American Heart Association, Ovid Technologies (Wolters Kluwer Health), Vol. 10, No. 1 ( 2021-01-05)
    Abstract: This study sought to investigate the safety of 3‐month dual antiplatelet therapy (DAPT) in patients receiving ultrathin sirolimus‐eluting stents with biodegradable polymer (Orsiro). Methods and Results The SMART‐CHOICE (Smart Angioplasty Research Team: Comparison Between P2Y12 Antagonist Monotherapy vs Dual Anti‐ platelet Therapy in Patients Undergoing Implantation of Coronary Drug‐Eluting Stents) randomized trial compared 3‐month DAPT followed by P2Y12 inhibitor monotherapy with 12‐month DAPT in 2993 patients undergoing percutaneous coronary intervention. The present analysis was a prespecified subgroup analysis for patients receiving Orsiro stents. As a post hoc analysis, comparisons between Orsiro and everolimus‐eluting stents were also done among patients receiving 3‐month DAPT. Of 972 patients receiving Orsiro stents, 481 patients were randomly assigned to 3‐month DAPT and 491 to 12‐month DAPT. At 12 months, the target vessel failure, defined as a composite of cardiac death, target vessel–related myocardial infarction, or target vessel revascularization, occurred in 8 patients (1.7%) in the 3‐month DAPT group and in 14 patients (2.9%) in the 12‐month DAPT group (hazard ratio [HR], 0.58; 95% CI, 0.24–1.39; P =0.22). In whole population who were randomly assigned to receive 3‐month DAPT (n=1495), there was no significant difference in the target vessel failure between the Orsiro group and the everolimus‐eluting stent group (n=1014) (1.7% versus 1.8%; HR, 0.96; 95% CI, 0.41–2.22; P =0.92). Conclusions In patients receiving Orsiro stents, clinical outcomes at 1 year were similar between the 3‐month DAPT followed by P2Y12 inhibitor monotherapy and 12‐month DAPT strategies. With 3‐month DAPT, there was no significant difference in target vessel failure between Orsiro and everolimus‐eluting stents. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02079194.
    Type of Medium: Online Resource
    ISSN: 2047-9980
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 2653953-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages