In:
Angiology, SAGE Publications, Vol. 72, No. 10 ( 2021-11), p. 986-993
Abstract:
We evaluated the angiographic parameter and clinical outcomes of drug-coated balloon (DCB) to assess the optimal angiographic criteria in de novo small vessel disease (SVD). Patients (n = 424, mean age: 64.4 ± 11.2 years, men: 69.8%) at 20 sites in Korea were prospectively enrolled. The primary end point was late luminal loss (LLL) at 9-month follow-up angiography. Secondary end points included restenosis rates, target lesion failure (TLF), and DCB-related thrombosis during the 12-month follow-up period. We included 403 patients for analysis excluding 21 patients who required bailout stenting. Baseline mean reference vessel .diameter was 2.52 ± 0.39 mm and mean minimal luminal diameter (MLD) was 0.71 ± 0.40 mm. The mean MLD was 1.54 ± 0.37 mm after DCB. Late luminal loss was −0.01 ± 0.43 mm and restenosis was noted in 26 patients (12.2%). Minimal luminal diameter 〉 1.6 mm and % diameter stenosis (DS ) 〈 45% after DCB was associated maintenance of MLD without LLL at 9-months. Multivariate analysis demonstrated that %DS at baseline and post-MLD was associated with the restenosis. During 12-month follow-up, TLF was 2.6% including 1 cardiac death, 1 myocardial infarction, and 10 ischemia-driven target lesion revascularizations. Drug-coated balloon showed a low restenosis and lower LLL despite high in-segment DS. Post-MLD and % DS may be helpful to get optimal results in de novo SVD after DCB.
Type of Medium:
Online Resource
ISSN:
0003-3197
,
1940-1574
DOI:
10.1177/00033197211015534
Language:
English
Publisher:
SAGE Publications
Publication Date:
2021
detail.hit.zdb_id:
2065911-8