    Abstract: Objective: To study the effects of different structures (solid/hollow) and pore diameters (300/600 μm) on bone ingrowth. Methods: Porous titanium alloy scaffolds (3.2 * 10.5 mm) were printed using electron beam melting. The implants were divided into either Hollow or Solid Group. The upper half of each implant was printed with a pore diameter of 600 μm while the bottom half was printed with a pore diameter of 300 μm. Visualization of the structural morphology was done using Scanning Electron Microscope (SEM). Cell proliferation was evaluated with the cell counting kit-8 assay and live/dead staining assay. The different lateral femoral condyles of 15 New Zealand rabbits were implanted with different groups of scaffolds. The rabbits were randomly sacrificed at the 4th, 8th, and 12th week postoperatively. Bone mineral density (BMD) and bone volume fraction (BV/TV) evaluation was completed by quantitative Micro-Computed Tomography (Micro-CT). Tissue histology were stained with toluidine blue to observe bone ingrowth under an optical microscope, and the percentage of new bone area were calculated using Image Pro-Plus 6.0. Results: SEM images showed a significant decrease in residual powder in the hollow implant and cell studies showed no obvious cytotoxicity for the Ti 6 Al 4 V scaffolds. Micro-CT reconstruction revealed high levels of new bone formation around the scaffolds. The trabeculae around the implants showed a gradual increase with each week, and new bone filled the scaffold pores gradually. BMD, BV/TV, and tissue histology revealed the 300 μm pore diameter is more conducive to bone ingrowth than the 600 μm ( p 〈 .05). Conclusion: Our study revealed that Ti 6 Al 4 V implants with hollow structure could reduce the residual metal powder and implants with 300 μm pore diameter were more effective on bone formation than a 600 μm.
    Type of Medium: Online Resource
    ISSN: 0885-3282 , 1530-8022
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2022
    detail.hit.zdb_id: 2072559-0
    SSG: 12
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages