Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    SAGE Publications ; 2018
    In:  Ultrasound Vol. 26, No. 2 ( 2018-05), p. 81-92
    In: Ultrasound, SAGE Publications, Vol. 26, No. 2 ( 2018-05), p. 81-92
    Abstract: To determine if a novel computer-generated metric, effective acceleration time, improves accuracy for detecting tardus parvus waveforms on spectral Doppler ultrasound. Methods Patients with echocardiography-confirmed aortic valve stenosis ( n = 132; 60 mild, 44 moderate, 28 severe) and matched controls ( n = 48) who underwent carotid Doppler ultrasound were identified through an imaging database search at a single medical center. A custom-built spectral analysis computer program generated effective acceleration time values for spectral Doppler waveforms in the carotid arteries and a receiver operating characteristic analysis was performed to determine the optimal median effective acceleration time cutoff value to detect tardus parvus waveforms. Two radiologists, blinded to subject disease status, reviewed and rated all carotid sonograms for presence of tardus parvus waveforms. Inter-rater variability was measured, and the accuracy of aortic valve stenosis detection with and without use of the effective acceleration time cutoff was calculated. Results Receiver operating characteristic analysis revealed an optimal effective acceleration time cutoff of ≥ 48 ms with a corresponding area under the curve of 0.77 (95% CI: 0.70–0.84). Use of the effAT cutoff demonstrated an accuracy of 74%. Accuracy of visual waveform interpretation by raters ranged from 43% to 61%. Inter-rater agreement in detection of tardus parvus waveforms was 76% (136/180 cases, K = 0.44, p  〈  0.001). Conclusions Detection of tardus parvus waveforms through visual interpretation of spectral Doppler waveform morphology is limited by low accuracy and moderate inter-rater variability. Use of a computer-generated median effective acceleration time cutoff value markedly improves diagnostic accuracy and avoids observer variability.
    Type of Medium: Online Resource
    ISSN: 1742-271X , 1743-1344
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2018
    detail.hit.zdb_id: 2163911-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages