    In: Anesthesia & Analgesia, Ovid Technologies (Wolters Kluwer Health), Vol. 132, No. 3 ( 2021-03), p. 707-716
    Abstract: Despite their usefulness in perioperative and acute care settings, factor-Xa inhibitor-specific assays are scarcely available, contrary to heparin anti-Xa assay. We assessed whether the heparin anti-Xa assay can (1) be used as a screening test to rule out apixaban, rivaroxaban, fondaparinux, and danaparoid levels that contraindicate invasive procedures according to current guidelines ( 〉 30 ng·mL −1 , 〉 30 ng·mL −1 , 〉 0.1 µg·mL −1 , and 〉 0.1 IU·mL −1 , respectively), (2) quantify the anticoagulant level if found significant, that is, if it exceeded the abovementioned threshold. METHODS: In the derivation cohort then in the validation cohort, via receiver operating characteristics (ROC) curve analysis, we evaluated the ability of heparin anti-Xa assay to detect levels of factor-Xa inhibitors above or below the abovementioned safety thresholds recommended for an invasive procedure (screening test). Among samples with relevant levels of factor-Xa inhibitor, we determined the conversion factor linking the measured level and heparin anti-Xa activity in a derivation cohort. In a validation cohort, the estimated level of each factor-Xa inhibitor was thus inferred from heparin anti-Xa activity. The agreement between measured and estimated levels of factor-Xa inhibitors was assessed. RESULTS: Among 989 (355 patients) and 756 blood samples (420 patients) in the derivation and validation cohort, there was a strong linear relationship between heparin anti-Xa activities and factor-Xa inhibitors measured level ( r = 0.99 [95% confidence interval {CI}, 0.99–0.99]). In the derivation cohort, heparin anti-Xa activity ≤0.2, ≤0.3, 〈 0.1, 〈 0.1 IU·mL −1 reliably ruled out a relevant level of apixaban, rivaroxaban, fondaparinux, and danaparoid, respectively (area under the ROC curve ≥0.99). In the validation cohort, these cutoffs yielded excellent classification accuracy (≥96%). If this screening test indicated relevant level of factor-Xa inhibitor, estimated and measured levels closely agreed (Lin’s correlation coefficient close to its maximal value: 95% CI, 0.99–0.99). More than 96% of the estimated levels fell into the predefined range of acceptability (ie, 80%–120% of the measured level). CONCLUSIONS: A unique simple test already widely used to assay heparin was also useful for quantifying these 4 other anticoagulants. Both clinical and economic impacts of these findings should be assessed in a specific study.
    Type of Medium: Online Resource
    ISSN: 0003-2999
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 2018275-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages