Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    SAGE Publications ; 2001
    In:  Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Vol. 215, No. 5 ( 2001-05-01), p. 459-469
    In: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, SAGE Publications, Vol. 215, No. 5 ( 2001-05-01), p. 459-469
    Abstract: Femoral bone remodelling, following total hip arthroplasty, is a clinically observed phenomenon attributed to the changed stress environment of the postoperative implanted hip. While this process cannot be avoided, there is concern as to its consequences on the long-term survival of hip joint replacements. Previous methods of studying remodelling, such as clinical or animal-based studies, or finite element analyses, have their limitations. The aim of this study is to develop experimental specimens incorporating bone resorption features typical of clinically successful implants. This work describes the use of computer aided design/manufacturing methods (CAD-CAM) to produce these specimens, based on modifying commercially available composite femurs. The procedures are investigated and verified for two different designs of cemented prostheses (Lubinus SPII and Müller Curved). Quantitative clinical data is used to define the remodelled geometry of a CAD model of the femur for each stem design. Composite femur specimens are machined using a three-axis milling machine, where each specimen can be accurately positioned using a custom-designed jig and a digitizer system. The accuracy of the process is assessed by analysing the deviation of the digitized premachined and postmachined surfaces of each specimen in relation to the CAD model. The results demonstrate that the procedure can be used for developing in vitro specimens with bone resorption features. These specimens are proposed as a useful tool for performing preclinical trials, such as load transfer or longevity/stability testing, with the advantage of modelling a long-term clinical situation, rather than solely analysing implanted femurs in an immediate postoperative state.
    Type of Medium: Online Resource
    ISSN: 0954-4119 , 2041-3033
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2001
    detail.hit.zdb_id: 2032763-8
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages