Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    British Institute of Radiology ; 2021
    In:  The British Journal of Radiology Vol. 94, No. 1118 ( 2021-02-01), p. 20190950-
    In: The British Journal of Radiology, British Institute of Radiology, Vol. 94, No. 1118 ( 2021-02-01), p. 20190950-
    Abstract: In-stent restenosis (ISR) after stenting for intracranial stenosis is a significant issue. This study aimed to evaluate the usefulness of the 3D T1-SPACE technique in the follow-up of patients after stent implantation. Methods: Fifteen patients with intracranial arterial stenosis were prospectively enrolled 6–8 months after stenting. Digital subtraction angiography (DSA) and 3D T1-SPACE imaging were performed to evaluate the degree of stenosis and the enhancement of the vessel wall. Bland–Altman plots were used to assess the agreement between the two imaging methods, and the Pearson correlation coefficient was calculated as a measure of the linear correlation. Results: Eight Enterprise stents and seven Wingspan stents were used in 15 patients. The follow-up DSA after 6–8 months showed that the degree of stenosis was 40% (range, 30–72%), and ISR occurred in 4 of 15 (26.7%) lesions. The degree of stenosis assessed using the 3D T1-SPACE imaging technique was 35% (range, 30–75%). All four patients with ISR demonstrated significant enhancement. The Pearson correlation coefficient between the two methods was 0.959 (p 〈 0.05), and the Bland–Altman plot showed that all data points were within the consistency limits ([Formula: see text] ± 1.96 s). Conclusion: As a non-invasive imaging modality, 3D T1-SPACE showed great consistency with DSA in measuring the degree of stenosis after intracranial stenting. It may be used as an optional method for detecting ISR. Advances in knowledge: This study evaluated the usefulness of 3D T1-SPACE technique in the follow-up of patients after stent implantation, which could be used as an optional and non-invasive method in detection of in-stent restenosis.
    Type of Medium: Online Resource
    ISSN: 0007-1285 , 1748-880X
    RVK:
    Language: English
    Publisher: British Institute of Radiology
    Publication Date: 2021
    detail.hit.zdb_id: 1468548-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages