Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Online-Ressource
    Online-Ressource
    Oxford University Press (OUP) ; 2004
    In:  Clinical Chemistry Vol. 50, No. 10 ( 2004-10-01), p. 1907-1920
    In: Clinical Chemistry, Oxford University Press (OUP), Vol. 50, No. 10 ( 2004-10-01), p. 1907-1920
    Kurzfassung: Background: Conceptionally, antibody microarrays are simply multiplexed sandwich immunoassays in a miniaturized format. However, from the amounts of capture antibodies used, it is not apparent whether such assays are ambient analyte (Ekins. Clin Chem 1998;44:2015–30) or mass-sensing devices (Silzel et al. Clin Chem 1998;44:2036–43). We evaluated multiplexed microarray sandwich assays for 24 mouse serum proteins in these terms within the boundaries of our experimental setup and based on theoretical considerations of the law of mass action. Methods: Capture antibodies for 24 mouse serum proteins were printed on planar microarray substrates. After incubation with mixtures of purified antigens for 1 or 18 h, mixtures of biotinylated detection antibodies were used. High assay sensitivity was achieved by use of resonance-light-scattering particles for signal generation. Titration curves were generated for assay volumes of 20, 40, and 80 μL, and detection limits were calculated and compared. The assays were modeled theoretically based on the amounts of capture antibodies and the assay volumes used. Results: As predicted, experimental variations of the assay volume by up to fourfold did not appreciably affect detection. Even for the most sensitive assay, & lt;2% of the analyte molecules present in the sample were captured and generated signal at the detection limit. However, increasing the sample incubation time from 1 to 18 h on average lowered the detection limit threefold. Conclusions: In our experimental setup, all 24 sandwich microarray assays fulfill the criteria of the “ambient analyte” regime because depletion of analyte molecules from the assay volume is insignificant.
    Materialart: Online-Ressource
    ISSN: 0009-9147 , 1530-8561
    Sprache: Englisch
    Verlag: Oxford University Press (OUP)
    Publikationsdatum: 2004
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz