    In:  Current Directions in Biomedical Engineering Vol. 5, No. 1 ( 2019-09-01), p. 441-443
    In: Current Directions in Biomedical Engineering, Walter de Gruyter GmbH, Vol. 5, No. 1 ( 2019-09-01), p. 441-443
    Kurzfassung: Insertion studies in artificial cochlea models (aCM) are used for the analysis of insertion characteristics of different cochlear implant electrode carrier (EC) designs by measuring insertion forces. These forces are summed forces due to the measuring position which is directly underneath the aCM. The current hypothesis is that they include dynamic friction forces during the insertion process and the forces needed to bend an initially straight EC into the curved form of the aCM. For the purposes of the present study, straight EC substitutes with a constant diameter of 0.7 mm and 20.5 mm intracochlear length were fabricated out of silicone in two versions with different stiffness by varying the number of embedded wires. The EC substitutes were inserted into three different models made of polytetrafluoroethylene (PTFE), each model showing only one constant radius. Three different insertion speeds were used (0.11 / 0.4 / 1.6 mm/s) with an automated insertion test bench. For each parameter combination (curvature, speed, stiffness) twelve insertions were conducted. Measurements included six full insertions and six paused insertions. Paused insertions include a ten second paused time interval without further insertion movement each five millimetres. Measurements showed that dynamic and static components of the measured summed forces can be identified. Dynamic force components increase with increased insertion speeds and also with increased stiffness of the EC substitutes. Both force components decrease with larger radius of the PTFE model. After the insertion, the EC substitutes showed a curved shape, which indicates a plastic deformation of the embedded wires due to the insertion into the curved models. The results can be used for further research on an analytical model to predict the insertions forces of a specific combination of selected parameters as insertion speed and type of EC, combined with given factors such as cochlear geometry.
    Materialart: Online-Ressource
    ISSN: 2364-5504
    Sprache: Englisch
    Verlag: Walter de Gruyter GmbH
    Publikationsdatum: 2019
    ZDB Id: 2835398-5
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz