Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Tumors of female reproductive system, Publishing House ABV Press, Vol. 18, No. 3 ( 2022-12-01), p. 14-23
    Abstract: Background. The accurate and early diagnosis of breast cancer can improve efficacy of the treatment. The standard diagnostic methods such as mammography, ultrasound, and magnetic resonance tomography have a pivotal role in the detection of breast tumors, however, in some cases, they have low diagnostic accuracy. Mammoscintigraphy (MSG) / molecular breast imaging (MBI) with tumor-specific radiopharmacy 99m Tc-Technetril in patients with breast cancer can considerably increase the accuracy of diagnosis. However, the diagnostic performance of MSG / MBI in the detection of different biological subtypes of breast cancer is still under investigation. Aim. To evaluate the accuracy of MSG / MBI with 99m Tc-Technetril in diagnosis of different biological subtypes of breast cancer. Materials and methods. The analysis included the results of MSG / MBI of 1080 patients (2154 mammary glands), who were examined for suspected breast cancer. MSG / MBI were performed 5–15 min after intravenous injection into the vein of one of the feet of 370–740 MBq of tumor-specific radiopharmacy 99m Tc-Technetril. Examinations performed from 2007–2020 was carried out on the emission computed tomography Forte (Philips); since 2020 the molecular visualization has been providing on the special gamma-camera Discovery NM750b (General Electric). The obtained data were evaluated by 2 experienced radiologists. Verification of changes in breasts was provided by morphological examination (1060 cases) or dynamic observation. Results. The sensitivity, specificity and overall accuracy of MSG / MBI were 90 %, 98 %, 95 % correspondingly. When diagnosing tumors with a diameter of up to 10 mm, the sensitivity of MSG / MBI was decreased to 83 %. In patients with various biological subtypes, the sensitivity of MSG / MBI was as follows: luminal A – 88 %; luminal B– – 91 %; luminal B+ – 92 %; triple negative – 93 %; HER2-positive – 96 %. The intensity of tumor uptake depended on the biological subtype of breast cancer. The average values of the 99m Tc-Technetril uptake coefficient were as follows: luminal A – 1.59; luminal B– – 1.71; luminal B+ – 1.95; triple negative – 1.93; HER2-positive – 2.22. Conclusion. Retrospective analysis indicate high diagnostic performance of MSG / MBI: sensitivity – 90 %, specificity – 98 %, accuracy – 95 %. There are significant differences in the intensity of 99m Tc-Technetril accumulation in tumors in patients with different biological subtypes of breast cancer ( p = 0.01–0.004). MSG / MBI characterized by significant differences in the sensitivity in the diagnosis of luminal A and HER2+ breast cancer subtypes: 88 % and 96 %, respectively ( p = 0.02).
    Type of Medium: Online Resource
    ISSN: 1999-8627 , 1994-4098
    URL: Issue
    Language: Unknown
    Publisher: Publishing House ABV Press
    Publication Date: 2022
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages