Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Online-Ressource
    Online-Ressource
    Frontiers Media SA ; 2022
    In:  Frontiers in Cardiovascular Medicine Vol. 9 ( 2022-3-16)
    In: Frontiers in Cardiovascular Medicine, Frontiers Media SA, Vol. 9 ( 2022-3-16)
    Kurzfassung: We sought to conduct a systematic review and meta-analysis of clinical adverse events in patients undergoing transcatheter aortic valve replacement (TAVR) with bicuspid aortic valve (BAV) vs. tricuspid aortic valve (TAV) anatomy and the efficacy of balloon-expandable (BE) vs. self-expanding (SE) valves in the BAV population. Comparisons aforementioned will be made stratified into early- and new-generation devices. Differences of prosthetic geometry on CT between patients with BAV and TAV were presented. In addition, BAV morphological presentations in included studies were summarized. Method Observational studies and a randomized controlled trial of patients with BAV undergoing TAVR were included according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. Results A total of 43 studies were included in the final analysis. In patients undergoing TAVR, type 1 BAV was the most common phenotype and type 2 BAV accounted for the least. Significant higher risks of conversion to surgical aortic valve replacement (SAVR), the need of a second valve, a moderate or severe paravalvular leakage (PVL), device failure, acute kidney injury (AKI), and stroke were observed in patients with BAV than in patients with TAV during hospitalization. BAV had a higher risk of new permanent pacemaker implantation (PPI) both at hospitalization and a 30-day follow-up. Risk of 1-year mortality was significantly lower in patients with BAV than that with TAV [odds ratio (OR) = 0.85, 95% CI 0.75–0.97, p = 0.01]. BE transcatheter heart valves (THVs) had higher risks of annular rupture but a lower risk of the need of a second valve and a new PPI than SE THVs. Moreover, BE THV was less expanded and more elliptical in BAV than in TAV. In general, the rates of clinical adverse events were lower in new-generation THVs than in early-generation THVs in both BAV and TAV. Conclusions Despite higher risks of conversion to SAVR, the need of a second valve, moderate or severe PVL, device failure, AKI, stroke, and new PPI, TAVR seems to be a viable option for selected patients with severe bicuspid aortic stenosis (AS), which demonstrated a potential benefit of 1-year survival, especially among lower surgical risk population using new-generation devices. Larger randomized studies are needed to guide patient selection and verified the durable performance of THVs in the BAV population.
    Materialart: Online-Ressource
    ISSN: 2297-055X
    Sprache: Unbekannt
    Verlag: Frontiers Media SA
    Publikationsdatum: 2022
    ZDB Id: 2781496-8
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz