Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Frontiers Media SA ; 2023
    In:  Frontiers in Neurology Vol. 14 ( 2023-7-27)
    In: Frontiers in Neurology, Frontiers Media SA, Vol. 14 ( 2023-7-27)
    Abstract: Automated lesion segmentation is increasingly used in acute ischemic stroke magnetic resonance imaging (MRI). We explored in detail the performance of apparent diffusion coefficient (ADC) thresholding for delineating baseline diffusion-weighted imaging (DWI) lesions. Methods Retrospective, exploratory analysis of the prospective observational single-center 1000Plus study from September 2008 to June 2013 ( clinicaltrials.org ; NCT00715533). We built a fully automated lesion segmentation algorithm using a fixed ADC threshold (≤620 × 10–6 mm 2 /s) to delineate the baseline DWI lesion and analyzed its performance compared to manual assessments. Diagnostic capabilities of best possible ADC thresholds were investigated using receiver operating characteristic curves. Influential patient factors on ADC thresholding techniques’ performance were studied by conducting multiple linear regression. Results 108 acute ischemic stroke patients were selected for analysis. The median Dice coefficient for the algorithm was 0.43 (IQR 0.20–0.64). Mean ADC values in the DWI lesion ( β  = −0.68, p   & lt; 0.001) and DWI lesion volumes ( β  = 0.29, p   & lt; 0.001) predicted performance. Optimal individual ADC thresholds differed between subjects with a median of ≤691 × 10 −6 mm 2 /s (IQR ≤660–750 × 10 −6 mm 2 /s). Mean ADC values in the DWI lesion ( β  = −0.96, p   & lt; 0.001) and mean ADC values in the brain parenchyma ( β  = 0.24, p   & lt; 0.001) were associated with the performance of individual thresholds. Conclusion The performance of ADC thresholds for delineating acute stroke lesions varies substantially between patients. It is influenced by factors such as lesion size as well as lesion and parenchymal ADC values. Considering the inherent noisiness of ADC maps, ADC threshold-based automated delineation of very small lesions is not reliable.
    Type of Medium: Online Resource
    ISSN: 1664-2295
    Language: Unknown
    Publisher: Frontiers Media SA
    Publication Date: 2023
    detail.hit.zdb_id: 2564214-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages