Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    In: Frontiers in Neuroscience, Frontiers Media SA, Vol. 16 ( 2022-12-20)
    Kurzfassung: This study aimed to investigate the changes in extracellular space (ECS) in cryptococcal brain granuloma and its pathological mechanism. Materials and methods The animal model of cryptococcal brain granuloma was established by injecting 1 × 10 6 CFU/ml of Cryptococcus neoformans type A suspension into the caudate nucleus of Sprague–Dawley rats with stereotactic technology. The infection in the brain was observed by conventional MRI scanning on days 14, 21, and 28 of modeling. The tracer-based MRI with a gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) as a magnetic tracer was performed on the rats with cryptococcal granuloma and the rats in the control group. The parameters of ECS in each area of cryptococcal brain granuloma were measured. The parameters of ECS in the two groups were compared by independent sample t -test, and the changes in ECS and its mechanism were analyzed. Results Up to 28 days of modeling, the success rate of establishing the brain cryptococcal granuloma model with 1 × 10 6 CFU/ml Cryptococcus neoformans suspension was 60%. In the internal area of cryptococcal granuloma, the effective diffusion coefficient D * was significantly higher than that of the control group ( t = 2.76, P & lt; 0.05), and the same trend showed in the volume ratio α ( t = 3.71, P & lt; 0.05), the clearance rate constant k ( t = 3.137, P & lt; 0.05), and the tracer half-life T 1/2 ( t = 3.837, P & lt; 0.05). The tortuosity λ decreased compared with the control group ( t = −2.70, P & lt; 0.05). At the edge of the cryptococcal granuloma, the D * and α decreased, while the λ increased compared with the control group ( D *: t = −6.05, P & lt; 0.05; α: t = −4.988, P & lt; 0.05; λ: t = 6.222, P & lt; 0.05). Conclusion The internal area of the lesion demonstrated a quicker, broader, and more extended distribution of the tracer, while the edge of the lesion exhibited a slower and narrower distribution. MRI tracer method can monitor morphological and functional changes of ECS in pathological conditions and provide a theoretical basis for the treatment via ECS.
    Materialart: Online-Ressource
    ISSN: 1662-453X
    Sprache: Unbekannt
    Verlag: Frontiers Media SA
    Publikationsdatum: 2022
    ZDB Id: 2411902-7
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz