Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Frontiers in Oncology, Frontiers Media SA, Vol. 10 ( 2021-2-22)
    Abstract: Glioblastoma Multiforme (GBM) is the most common primary brain cancer and one of the most lethal tumors. Theoretically, modern radiotherapy (RT) techniques allow dose-escalation due to the reduced irradiation of healthy tissues. This study aimed to define the adjuvant maximum tolerated dose (MTD) using volumetric modulated arc RT with simultaneous integrated boost (VMAT-SIB) plus standard dose temozolomide (TMZ) in GBM. Methods A Phase I clinical trial was performed in operated GBM patients using VMAT-SIB technique with progressively increased total dose. RT was delivered in 25 fractions (5 weeks) to two planning target volumes (PTVs) defined by adding a 5-mm margin to the clinical target volumes (CTVs). The CTV 1 was the tumor bed plus the MRI enhancing residual lesion with 10-mm margin. The CTV 2 was the CTV 1 plus 20-mm margin. Only PTV 1 dose was escalated (planned dose levels: 72.5, 75, 77.5, 80, 82.5, 85 Gy), while PTV 2 dose remained unchanged (45 Gy/1.8 Gy). Concurrent and sequential TMZ was prescribed according to the EORTC/NCIC protocol. Dose-limiting toxicities (DLTs) were defined as any G ≥ 3 non-hematological acute toxicity or any G ≥ 4 acute hematological toxicities (RTOG scale) or any G ≥ 2 late toxicities (RTOG-EORTC scale). Results Thirty-seven patients (M/F: 21/16; median age: 59 years; median follow-up: 12 months) were enrolled and treated as follows: 6 patients (72.5 Gy), 10 patients (75 Gy), 10 patients (77.5 Gy), 9 patients (80 Gy), 2 patients (82.5 Gy), and 0 patients (85 Gy). Eleven patients (29.7%) had G1-2 acute neurological toxicity, while 3 patients (8.1%) showed G ≥ 3 acute neurological toxicities at 77.5 Gy, 80 Gy, and 82.5 Gy levels, respectively. Since two DLTs (G3 neurological: 1 patient and G5 hematological toxicity: 1 patient) were observed at 82.5 Gy level, the trial was closed and the 80 Gy dose-level was defined as the MTD. Two asymptomatic histologically proven radionecrosis were recorded. Conclusions According to the results of this Phase I trial, 80 Gy in 25 fractions accelerated hypofractionated RT is the MTD using VMAT-SIB plus standard dose TMZ in resected GBM.
    Type of Medium: Online Resource
    ISSN: 2234-943X
    Language: Unknown
    Publisher: Frontiers Media SA
    Publication Date: 2021
    detail.hit.zdb_id: 2649216-7
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages