Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Pensoft Publishers ; 2019
    In:  Nuclear Energy and Technology Vol. 5, No. 1 ( 2019-03-20), p. 31-38
    In: Nuclear Energy and Technology, Pensoft Publishers, Vol. 5, No. 1 ( 2019-03-20), p. 31-38
    Abstract: Steam generators for NPPs are the important large-sized metal consuming equipment of nuclear power installations. Efficiency of steam generator operation determines the overall service life of the whole nuclear facility. The main aim of the current study is to analyze advantages and shortcomings of horizontal and vertical types of steam generator design. This analysis is aimed at the development of recommendations for designing advanced steam generators for future Russian units of NPPs with VVER reactors of increased power. Design solutions and fifty-year experience of operation of 400 steam generators of horizontal type accepted in Russia and of vertical type applied by Westinghouse, Combustion Engineering, Siemens, Mitsubishi, Doosan were analyzed within the framework of the present study. Advantages and drawbacks of both types of equipment determining the development of conditions of the operating processes were also identified and systematized. Currently NPPs equipped with VVER are characterized with extended surface area of containment shells due to the application of four-loop design configuration and horizontal-type steam generators. It was established that steam generator equipment of horizontal type is characterized by such inherent disadvantages of design, technological and operational nature as the following: 1) small height and volume of the vapor space above the evaporation surface reducing separation capabilities and the capacity of the equipment as a whole; 2) impossibility of organizing separate single-phase pre-boiling section. Because of the above, horizontal steam generators with dimensions permissible for railroad transportation and, for VVER-1200 with reactor vessel diameter equal to 5 m, by water transport as well, have exhausted the possibilities for further significant increase of the per unit electric power. The demonstrated advantages of vertical-type steam generators were as follows: 1) absence of stagnant zones within the second cooling circuit, and, consequently, of hold-ups in them; 2) uniformity of heat absorption efficiency of the heating surface ensuring, as well, improved conditions for moisture separation; 3) high degree of moisture removal from steam-water mixture due to the combination of moisture separating elements of chevron and swirl-vane types; 4) increased temperature drop with parameters of generated steam elevated by 0.3 – 0.4 MPa. Conclusion was made on the advisability of introduction of steam generators with vertical-type layout in the Russian nuclear power generation. Practical tasks that need to be addressed in order to ensure introduction of vertical steam generators at NPPs with high-power VVER reactors were formulated.
    Type of Medium: Online Resource
    ISSN: 2452-3038
    Language: Unknown
    Publisher: Pensoft Publishers
    Publication Date: 2019
    detail.hit.zdb_id: 2858592-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages