In:
Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 52, No. 5 ( 2003), p. 1203-
Abstract:
A temporalspatial resolution system, which is composed of a slit, infra scintillator, optical fibre array, streak camera, image intensifier, etc., is constructed for the diagnosis of the Zpinch plasma. This system can effectively shield visible light and has an advantage of gaining flat response in the interested region of xray energy. The designed parameters and experimental results of gaspuff Zpinch are presented in this paper.
Type of Medium:
Online Resource
ISSN:
1000-3290
,
1000-3290
Language:
Unknown
Publisher:
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Publication Date:
2003