Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    SAGE Publications ; 2014
    In:  Technology in Cancer Research & Treatment Vol. 13, No. 3 ( 2014-06), p. 259-267
    In: Technology in Cancer Research & Treatment, SAGE Publications, Vol. 13, No. 3 ( 2014-06), p. 259-267
    Abstract: Abdominal compression using a pneumatic abdominal compression belt developed in-house has been used to reduce respiratory motion of patients undergoing hypofractionated or single fraction stereotactic radio-ablative therapy for abdominal cancers. The clinical objective of belt usage was to reduce the cranial-caudal (CC) respiratory motion of the tumor to 5 mm or less during both CT simulation and treatment. A retrospective analysis was done to determine the effectiveness of the device and associated clinical procedures to reduce the CC respiratory motion of the tumor. Materials and Methods: 42 patients treated for tumors in the liver (30), adrenal glands (6), pancreas (3) and lymph nodes (3) using high dose hypofractionated radiotherapy between 2004 and the present were eligible for analysis. All patients had 2–3 radiopaque fiducial markers implanted near the tumor prior to simulation, or had clips from prior surgery. Integral to the belt is an inflatable air bladder that is positioned over the abdomen. The pneumatic pressure was set to a level in consultation with the patient. The CC motion was measured fluoroscopically with and without pneumatic pressure. Pneumatic pressure was used at all treatments to reduce to CC motion to that achieved at simulation. Results: The mean CC motion with the belt in place, but no additional air pressure was 11.4 mm with a range of 5–20 mm. With the pressure applied, the mean CC motion was reduced to 4.4 mm with a range of 1–8 mm ( P-value 〈 0.001). The clinical objective of reducing the CC motion of the tumor to a maximum excursion of 5 mm or less was achieved in 93% of cases. Conclusion: The use of a pneumatic compression belt and associated clinical procedures was found to result in a significant and frequently substantial reduction in the CC motion of the tumor.
    Type of Medium: Online Resource
    ISSN: 1533-0346 , 1533-0338
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2014
    detail.hit.zdb_id: 2146365-7
    detail.hit.zdb_id: 2220436-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages