Format:
1 Online-Ressource
Content:
Abstract: Purpose〈br〉Reconstruction of orbital wall fractures is demanding and has improved dramatically with the implementation of new technologies. True-to-original accuracy of reconstruction has been deemed essential for good clinical outcome, and reasons for unfavorable clinical outcome have been researched extensively. However, no detailed analysis on the influence of plate position and surface contour on clinical outcome has yet been published.〈br〉〈br〉Materials and methods〈br〉Data from a previous study were used for an ad-hoc analysis to identify predictors for unfavorable outcome, defined as diplopia or differences in globe height and/or globe projection of 〉2 mm. Presumed predictors were implant surface contour, aberrant implant dimension or position, accuracy of reconstructed orbital volume, and anatomical fracture topography according to the current AO classification.〈br〉〈br〉Results〈br〉Neither in univariable nor in multivariable regression models were unfavorable clinical outcomes associated with any of the presumed radiological predictors, and no association of the type of implant, i.e., standard preformed, CAD-based individualized and non−CAD-based individualized with its surface contour could be shown.〈br〉〈br〉Conclusion〈br〉These data suggest that the influence of accurate mechanical reconstruction on clinical outcomes may be less predictable than previously believed, while the role of soft-tissue−related factors may have been underestimated
Note:
Journal of cranio-maxillofacial surgery. - 46, 4 (2018) , 578-587, ISSN: 1878-4119
Language:
English
DOI:
10.1016/j.jcms.2018.01.007
URN:
urn:nbn:de:bsz:25-freidok-1470369
URL:
https://doi.org/10.1016/j.jcms.2018.01.007
URL:
https://nbn-resolving.org/urn:nbn:de:bsz:25-freidok-1470369