Content:
An analysis of a point source bubbler system used to induce local melting of an ice cover is presented. The analysis leads to a numerical simulation programmed in FORTRAN which may be used to predict the effectiveness of such systems. An example application is presented using a typical record of average daily air temperatures. The FORTRAN program for the point source simulation as well as a FORTRAN program for line source systems are included in the Appendix.
Note:
CONTENTS
Abstract
Preface
Introduction
Outline of analysis
Plume analysis
Heat transfer analysis
Temperature of impinging plume
Heat transfer coefficient
Melting of the ice cover
Simulation example
Thermal reserve analysis
Literature cited
Appendix