Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: European Spine Journal, Springer Science and Business Media LLC, Vol. 31, No. 10 ( 2022-10), p. 2587-2596
    Abstract: The present study aimed to assess the feasibility, safety and accuracy of navigated spinopelvic fixation with focus on S2-alar-iliac screws (S2AIS) and tricortical S1 pedicle screw implantation with the use of high-resolution three-dimensional intraoperative imaging and real-time spinal navigation. Methods Patients undergoing navigated intraoperative CT-based spinopelvic stabilization between January 2016 and September 2019 were included. Pelvic fixation was achieved by implantation of S2AIS or iliac screws (IS). S1 screws were implanted with the goal of achieving tricortical purchase. In all cases, instrumentation was performed with real-time spinal navigation and intraoperative screw positioning was assessed using intraoperative computed tomography (iCT), cone-beam CT (CBCT) and robotic cone-beam CT (rCBCT). Screw accuracy was evaluated based on radiographic criteria. To identify predictors of complications, univariate analysis was performed. Results Overall, 52 patients (85%) received S2AIS and nine patients (15%) received IS instrumentation. Intraoperative imaging and spinal navigation were performed with iCT in 34 patients, CBCT in 21 patients and rCBCT in six patients. A total number of 10/128 (7.8%) iliac screws underwent successful intraoperative correction due to misalignment. Tricortical purchase was successfully accomplished in 58/110 (53%) of the S1 screws with a clear learning curve in the course of time. S2AIS implantation was associated with significantly fewer surgical side infection-associated surgeries. Conclusions Real-time navigation facilitated spinopelvic instrumentation with increasing accuracy of S2AIS and tricortical S1 screws. Intraoperative imaging by iCT, CBCT or rCBCT permitted screw assessment with the chance of direct navigated revision of misplaced iliac screws to avoid secondary screw revision surgery.
    Type of Medium: Online Resource
    ISSN: 0940-6719 , 1432-0932
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2022
    detail.hit.zdb_id: 1472721-3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages